Image Processing forScanner 1500 andScanner 2500User’s GuideA-63055
A-63055 December 1999 4Resolution A3 A4 A5 A6 B4 B5 B6 Ledger Legal Letter100 dpi 0 0 0 0 0 0 0 0 0 0200 dpi 8 0 0 0 8 0 0 8 8 0300 dpi 32 16 8 0 24
A-63055 December 1999 5ISIS DriverInstallationThe ISIS driver is included with the scanner. You can install the driverfrom the CD.After installation
A-63055 December 1999 6Scanner SettingsDialog BoxThis section describes the features and buttons in the ScannerSettings dialog box.The Scanner Setti
A-63055 December 1999 7ModeChoose a grayscale or binary (black and white) scanning format in theMode drop-down list box. Select the format that is b
A-63055 December 1999 8DitherDithering is a technique for reproducing halftone images, such as aphoto, in binary mode.Two pixel levels are used to r
A-63055 December 1999 9Dots per inch(Resolution)Dots per inch (dpi) indicates the scanning resolution, which largelydetermines the quality of the sc
A-63055 December 1999 10BrightnessThis function allows you to adjust the image brightness, making itlighter or darker. There are two Brightness mode
A-63055 December 1999 11ContrastThe Contrast option sets the image contrast by adjusting the differencebetween black and white, thereby making an im
A-63055 December 1999 12Region SelectionYou can specify single-sided (simplex) or double-sided (duplex)scanning in the Region Selection group box.NO
A-63055 December 1999 13Specifying an Area To capture a portion of an image, click on the Area button to accessthe Set Scanning Area dialog box. Are
ISIS is a registered trademark of Pixel Translations, a division of InputSoftware, Inc.Windows and Windows NT are either registered trademarks ortrade
A-63055 December 1999 14Kodak ScannerSpecial FeaturesDialog BoxThis section describes the features and buttons in the Kodak ScannerSpecial Features
A-63055 December 1999 15The Kodak Scanner Special Features dialog box shown below appearswhen the Scanner 2500 is selected in the Scanner list.
A-63055 December 1999 16Buttons in theKodak Scanner SpecialFeatures Dialog BoxFollowing are descriptions of the buttons in the Kodak Scanner Special
A-63055 December 1999 17Image EmphasisImage Emphasis allows you to adjust the softness or sharpness ofthe scanned image. Choose one of the following
A-63055 December 1999 18GammaThe Gamma option allows you to define the gamma curve setting fornormal scanning and computer screen viewing. Choose on
A-63055 December 1999 19Long PaperWhen Long Paper is enabled, a lengthy type of document, such as anoil drill chart or a cardiogram, can be captured
A-63055 December 1999 20The length that can be scanned is determined by the memory size.ScannerMemorydpiDocumentWidthLongestDocument SizeComments8 M
A-63055 December 1999 21Read Deskew DataEnable Read Deskew Data to detect the skewing of a document andnotify the application when a skewed document
A-63055 December 1999 22Mirror ImageSelect Mirror Image to flip scanned images to create mirror images. Original
A-63055 December 1999 23White LevelFrom PaperWhen White Level From Paper is on, the first 3 mm of eachdocument is analyzed and the background bright
A-63055 December 1999 iContentsIntroduction ...1Features...
A-63055 December 1999 24Binary ModeAutomatic ThresholdSelecting Automatic Threshold automatically sets Brightness,Contrast, White Level From Paper,
A-63055 December 1999 25Manual Feed ModesThe Manual Feed Modes group box allows you to configure thefeeder in different ways, from a manual feed mod
A-63055 December 1999 26Scanner InformationThe Counter and Status buttons in the Scanner Information groupbox allow you to check the scan count and
A-63055 December 1999 27Click on the Status button to access the Scanner Status dialog box toview roller cleaning and replacement guidelines.Refer t
A-63055 December 1999 28BarcodeThe scanner can read barcodes. The barcode data is analyzed andthe information is sent in ASCII code to an applicatio
A-63055 December 1999 294. Check the Enable Barcode box.5. Select the barcode region in the Barcode Settings For drop-downlist box.Ten regions can
A-63055 December 1999 309. Set the barcode area:• X-Position to Begin Search—must be 10 mm (0.39 inches) tothe left of the first barcode data to b
A-63055 December 1999 31Detecting Patch CodesPatch codes can be used to index documents via the industry standardpatch codes ll, lll, and T.The patc
A-63055 December 1999 32The Barcode Parameters dialog box lists the Front Side and BackSide settings.4. Choose the direction of scanning (Horizonta
A-63055 December 1999 33Printing a Counter, Date,Time, or Fixed StringUse the following strings to print any combination of a counter, a date,a time
A-63055 December 1999 iiLength Control...18Long Paper...
A-63055 December 1999 34Printing Start PositionPrinting is done vertically from the top of the paper. The character top(“A” in the diagram below) po
A-63055 December 1999 35Setting up forDocument Printing1. Click on the More button to access the Scanner Special Featuresdialog box.2. Click on th
A-63055 December 1999 36Counter Click on the Counter button in the Imprinter Parameters dialog box toaccess the Counter dialog box to view the curre
A-63055 December 1999 37CompressionScanned image data can be compressed to decrease file sizes. WhenCompression is specified, files transmitted from
A-63055 December 1999 38TWAIN Data SourceInstallationThe TWAIN Data Source is included with the scanner. You can installthe driver from the CD.After
A-63055 December 1999 39Kodak Twain DriverDialog BoxThis section describes the features and buttons in the Kodak TwainDriver dialog box.The Kodak Tw
A-63055 December 1999 40The Kodak Twain Driver dialog box shown below appears when theScanner 2500 is selected in the Scanner list.
A-63055 December 1999 41Buttons in theKodak Twain DriverDialog BoxFollowing are descriptions of the buttons in the Kodak Twain Driverdialog box.Scan
A-63055 December 1999 42SideYou can specify single-sided or double-sided scanning in the Sidegroup box by selecting the Simplex or Duplex radio butt
A-63055 December 1999 43Image TypeChoose a grayscale or binary (black and white) scanning format in theImage Type drop-down list box. Select the for
A-63055 December 1999 iiiTWAIN Data Source...38Installation...
A-63055 December 1999 44Paper SizeThis function determines the scanning area by a pre-determined size.The default paper size is set when a scanner i
A-63055 December 1999 45Creating a New Paper Size1. Type the paper name, width, and length into the appropriate textboxes in the Free Paper Name/Si
A-63055 December 1999 46Halftone (Dither)Dithering is a technique for reproducing halftone images, such as aphoto, in binary mode.Two pixel levels a
A-63055 December 1999 47BrightnessThe Brightness option allows you to adjust the image brightness,making it lighter or darker.Adjust the brightness
A-63055 December 1999 48ContrastThe Contrast option sets the image contrast by adjusting the differencebetween black and white, thereby making an im
A-63055 December 1999 49Sub AreaYou can define a brightness level and dither setting for a specific areaof an image that is different from the brigh
A-63055 December 1999 50Specifying an Area To capture a portion of an image, click on the Sub Area button in theFront Side Settings group box or in
A-63055 December 1999 51More SettingsDialog BoxThis section describes the features and buttons in the More Settingsdialog box. This dialog box is ac
A-63055 December 1999 52The More Settings dialog box shown below appears when theScanner 2500 is selected in the Scanner list.
A-63055 December 1999 53Buttons in theMore SettingsDialog BoxFollowing are descriptions of the buttons in the More Settingsdialog box.Imprinter Clic
A-63055 December 1999 ivImage Emphasis ...56Scanner Status...
A-63055 December 1999 54White LevelWhen White Level is on, the first 3 mm of each document is analyzedand the background brightness level is adjuste
A-63055 December 1999 55GammaThe Gamma option allows you to define the gamma curve setting fornormal scanning and computer screen viewing. Choose on
A-63055 December 1999 56LampSelect Red in the Lamp box to allow the scanner to perform reddropout color. The green lamp is the normal setting. When
A-63055 December 1999 57Scanner StatusThe Counter and Warning buttons in the Scanner Status group boxallow you to check the scan count and roller st
A-63055 December 1999 58Click on the Warning button to access the Warning Status dialog box toview roller cleaning and replacement guidelines.Refer
A-63055 December 1999 59Mirror ImageSelect Mirror Image to flip scanned images to create mirror images Original
A-63055 December 1999 60Automatic Separation(Halftone Mode)When Automatic Separation is enabled, the scanner automaticallyrecognizes and separates t
A-63055 December 1999 61Fit to PageSelecting Fit to Page allows you to specify whether documents arescanned at actual size or reduced (Fit to Page)
A-63055 December 1999 62Stop at SkewWhen Stop at Skew is enabled, the scanner stops scanning when askewed document is detected.NOTE: This feature is
A-63055 December 1999 63Document Printer(Imprinter)The Imprinter button in the Scanner Special Features dialog boxallows you to access the Imprinter
A-63055 December 1999 1IntroductionKodak’s low volume production scanners include image processingtechnology that can improve image quality and some
A-63055 December 1999 64Printing a Counter, Date,Time, or Fixed StringUse the following strings to print any combination of a counter, a date,a time
A-63055 December 1999 65Printing Start PositionPrinting is done vertically from the top of the paper. The character top(“A” in the diagram below) po
A-63055 December 1999 66Setting up forDocument Printing1. Click on the More button to access the More dialog box.2. Click on the Imprinter button
A-63055 December 1999 67Counter Click on the Counter button in the Imprinter Parameters dialog box toaccess the Counter dialog box to view the curre
EASTMAN KODAK COMPANYDocument ImagingRochester, New York 14650Kodak, Digital Science, and the ds monogramsymbol, are trademarks of Eastman KodakCompan
A-63055 December 1999 2Scanner 1500 Scanner 2500FeatureISIS TWAIN ISIS TWAINAreaBarcodeBinary Mode / Automatic ThresholdBrightnessCompressionContras
A-63055 December 1999 3MemoryRequirementsThe Scanner 1500 and the Scanner 2500 both have 8 MB of memoryalready installed. This may be sufficient for